OTHER DOSE RATE METERS
 
 
SCINTOMAT 6134A 1. SCINTOMAT 6134A

for photon radiation (gamma- and X-radiation), with detachable scintillation probe, including batteries (three D cells 1.5V IEC LR20).
Analog range: 0.01 µSv/h - 15 Sv/h
Energy range 6134A: 25 keV - 1.3 MeV (within angular range of ± 45°)
Energy range 6134A/H: 28 keV - 7 MeV (within angular range of ± 60°)
- Hx model: 6134A
- H*(10) model: 6134A/H
Optional accessory: 2-line-mini-recorder for graphical recording of measurement.

 

2. SCINTOMAT 6134

for photon radiation (gamma- and X-radiation), with integrated scintillation probe, including batteries (four D cells 1.5V IEC LR20).
Analog range: 0.02 µSv/h - 30 mSv/h
Energy range 6134: 20 keV - 1.3 MeV (within angular range of ± 45°)
Energy range 6134/H: 20 keV - 7 MeV (within angular range of ± 60°)
- Hx model: 6134
- H*(10) model: 6134/H

 

3. TELETECTOR 6112B-100

for beta and photon radiation (gamma- and X-radiation), Hx model. Telescope extendible to a length of approx. 4 m. Including batteries (four C cells 1,5V IEC LR14).
Analog range: 0 - 10 Sv/h
Energy range: 80 keV - 2 MeV

 

4. TELETECTOR 6112D-100

for beta radiation and photon radiation (gamma- and X-radiation). Telescope extendible to a length of approx. 4 m. Including batteries (four C cells 1,5V IEC LR14).
Digital range: 0.01 µSv/h - 9999 mSv/h
Energy range: 80 keV - 2 MeV
- Hx model: 6112D-100
- H*(10) model: 6112D-100/H

 

5. TELETECTOR 6112M

for beta radiation and photon radiation (gamma- and X-radiation). Fully graphic LC-Display, stores up to 450 measured values, serial interface. Telescope extendible to a length of approx. 4 m. Including batteries (four C cells 1,5V IEC LR14).
Analog range: 0.1 µSv/h - 10 Sv/h
Digital range: 0.01 µSv/h - 10 Sv/h
Energy range 6112M: 65 keV - 1.3 MeV
Energy range 6112M/H: 45 keV - 1.3 MeV
- Hx model: 6112M
- H*(10) model: 6112M/H

 

6. HIGH DOSE RATE MEASURING DEVICE 665.1

for photon radiation (gamma- and X-radiation), Hx model, with Ionisation Chamber 665.1.2, including 30 m special cable, cable drum and trolley, charging unit, accumulators.
Analog range: 0.01 Sv/h - 15 kSv/h
Energy range: 80 keV - 3 MeV
Optional accessory: 2-line-mini-recorder for graphical recording of measurement.

 

7. GAMMA MONITOR 632.1

for photon radiation (gamma- and X-radiation), Hx model, including probe directly plugged into the instrument.
Analog range: 0.1 µSv/h - 10.000 µSv/h
Energy range: 60 keV - 2 MeV
power supply: AC 230V, 50 Hz, 0.2 A