PERSONAL DOSIMETERS
 
ELECTRONIC ALARMING DOSIMETER ALADOXNEW: Electronic Personal Dosimeters of the ALADOX series to measure the Personal Dose Equivalent Hp(10) caused by photon radiation (gamma and X-radiation), successor of the ALADOS and 219.x series. The robust aluminium die-cast housing was taken over from the ALADOS, whereas the electronics represent a completely new design. The ALADOX series provides more (eXtended) functions at even lower power consumption (approx. 5000 operating hours with a 9V alkaline battery). All ALADOX models provide: sophisticated precautions against battery failure (after power disruption, measured values will be retrieved when the device is switched on again) - permanent monitoring of detector, battery voltage, and device temperature - test mode allowing a very convenient radiological check - archive containing the data of the last 105 uses (reading the archive requires a dosimeter reader) - integrated piezo speaker emitting short melodies to guide the user and intense siren-like tones in case of warnings.

1. ELECTRONIC ALARMING DOSIMETER  ALADOX

for the quantity Hp(10) caused by photon radiation, choice of ten fixed threshold pairs for dose and dose rate, permanent digital dose indication, on keystroke indication of a sequence of measured data (time remaining until dose alarm - battery voltage - current, maximum and average dose rate - alarm thresholds - device temperature - total device dose), permanent dose memory (can be disabled), audible single pulse detection (can be disabled), programming mode to adapt the device to individual requirements, including 9V-battery (IEC 6LR61).
Dose range: 0.000 mSv - 9999 mSv
Ten threshold pairs from 0.010 mSv / 0.2 mSv/h to 10.00 mSv / 10 mSv/h
Energy range: 65 keV - 3 MeV 
Angular range: ±60°
Temperature range: -30°C - +60°C

 

2. ELECTRONIC ALARMING DOSIMETER  ALADOX-F (version for fire brigades)

for the quantity Hp(10) caused by photon radiation, choice of four fixed dose alarm thresholds, permanent indication of dose alarm threshold, on keystroke indication of a sequence of measured data (time remaining until dose alarm - battery voltage - dose - maximum and average dose rate - device temperature - total device dose), dose is cleared when the device is switched off, programming mode to select the dose alarm threshold which shall be valid after switching on, including 9V-battery (IEC 6LR61).
Dose range: 0.000 mSv - 9999 mSv
Dose alarm thresholds: 1mSv / 15mSv / 100mSv / 250mSv
Energy range: 65 keV - 3 MeV 
Angular range: ±60°
Temperature range: -30°C - +60°C

3. ELECTRONIC ALARMING DOSIMETER  ALADOX-SYS (system dosimeter)

for the quantity Hp(10) caused by photon radiation, specially designed for use as part of an electronic personal dosimetry system with dosimeter readers and a central dosimetry computer, two states »out of controlled area« and »in controlled area«, programmable alarm thresholds, programmable identification number and job number, on keystroke indication of a sequence of measured data (time remaining until dose main alarm - battery voltage - current, maximum and average dose rate - identification number - alarm thresholds - device temperature - total device dose), autarkic mode (use without any dosimeter reader in special or emergency cases), including 9V-battery (IEC 6LR61).
Dose range: 0.000 mSv - 9999 mSv
Four freely programmable dose alarm thresholds (three pre-alarms and one main alarm which cannot be reset)
One freely programmable dose rate alarm threshold
Energy range: 65 keV - 3 MeV
Angular range: ±60°
Temperature range: -30°C - +60°C


PEN DOSIMETERS SEQ5 / SEQ6R4. PEN DOSIMETERS SEQ5 / SEQ6R

for photon radiation (gamma- and X-radiation), Hx models, various types with full scales ranging from 1 mSv to 2 Sv. Requires charging unit CAT6 for resetting dose. Radiological check with check device 652.1.

NOTE: Production of pen dosimeters has been discontinued. Some remaining stock is still available.